**This project/subdivision is subject to the Unified Development Ordinance (UDO) due to the timing of its initial entitlements.
MA 21-06 - APPROVED 02-01-2022 - A Map Amendment (Rezoning) request to change the zoning from Wake County's Residential 30 (R30) District to the Town of Rolesville's Unified Development Ordinance (UDO) Residential 3 Conditional District (R3-CZ). The proposed zoning condition limits the residential development to single family attached (townhomes) and detached housing and maximums of 27 single-family detached dwellings and 71 single-family attached (townhome) dwelling units.
- On January 4, 2022, the Town Board of Commissioners held a public hearing, and voted 3-2 on a motion to Approve MA 21-06.
- On February 1, 2022, the Town Board of Commissioners Approved a revised/updated set of Conditions of Approval (dated ______ ).
ANX 21-04 - APPROVED 01-04-2022 - Voluntary Annexation Petition to annex 32.59 acres into the Town Corporate limits. On January 4, 2022, the Town Board of Commissioners held a public hearing, and voted 3-2 on a motion to Approve ANX 21-04.
PSP-23-01 - Preliminary Subdivision Plat to subdivision 32.819 acres zoned R3-CZ into 27 Single-family detached dwelling lots, 64 Single-family Attached (Townhome) lots, and multiple (TBD) lots for common open spaces and/or stormwater management/utilities.
- 1st Submittal rcvd December 2022; on TRC-STAFF Review in January; comments published on 02/08/2023.
- 2nd Submittal rcvd NOVEMBER 2023; on TRC-STAFF Review in NOVEMBER; comments published on 12/06/2023.
- 3rd Submittal rcvd December 26, 2023; on TRC-STAFF Review in JANUARY 2024; comments published on 02/05/2024.
Documents
Map Amendment (Rezoning) MA 21-06 / Tucker Wilkins - 1st Submittal
Map Amendment (Rezoning) MA 21-06 / Tucker Wilkins - 2nd Submittal
Voluntary Annexation ANX 21-04
MA 21-06 - Planning Board Agenda
MA 21-06 - Town Board Agenda 2022-01-04
MA 21-06 - Town Board Agenda 2022-02-01
MA 21-06 - Final Approval
Preliminary Subdivision Plat PSP-23-01 - 1st Submittal
- V1 - Proposed Preliminary Plat, dated 12-1-2022
- V1 - Comments SUMMARY - READ FIRST
- V1 - Comments - PLANNING - Markups of Plat set
- V1 - Comments-ENGINEERING Memo dated 1-30-23
- V1 - Comments-ENGINEERING Mark-ups
- V1 - Comments-FIRE report
- V1 - Comments - PARKS plan excerpts
- V1 - Comments-COR-PUD Markups of 2 sheets
Preliminary Subdivision Plat PSP-23-01 - 2nd Submittal
- V2 - Response to Planning mark-ups
- V2 - Response to Engineering mark-ups
- V2 - Response to WC Fire comments
- V2 - Response to COR-PUD mark-ups
- V2 - Revised Prelim Plat dated 11-02-2023
- V2 - Comments-SUMMARY - READ FIRST
- V2 - Comments-Planning Staff - Open space exhibit
- V2 - Comments-Planning Staff - Sheet 6.0 sketch
- V2 - Comments-ENGINEERING - Memo dated 11-30-23
- V2 - Comments-ENGINEERING - Mark-ups
- V2 - Comments-CORPUD - mark-up Sht 5.0
Preliminary Subdivision Plat PSP-23-01 - 3rd Submittal
- V3 - Response to Comments SUMMARY (all)
- V3 - Response to Engineering comments
- V3 - Response to CORPUD markups
- V3 - Response to PLNG Sht 6.0 mark-ups
- V3 - Response to PLNG open space mark-ups
- V3 - Prelim Plat rvsd dated 12-22-2023
- V3 - Comments SUMMARY - READ FIRST
- V3 - Comments-ENGINEERING Memo
- V3 - Comments-ENGINEERING mark-ups